To set equipment properties
- Double
click on the Flash. The Flash Tank properties dialog appears.
- Enter values necessary to define the equipment's performance.
- Set a flash pressure less than the inlet stream's pressure. For this example set
it to 35 psig.
- Press OK. The equipment properties are saved and they are used when
running the model.