Recovery - Two Stage Crystallizer Body Model

The Two Stage Crystallizer Body model can be used to simulate a combination of two crystallizers. One is flashing heavy liquor the other one weak liquor.
The Liquor_In, Liquor_Out for one side and Steam_Out streams are required, second side is optional.

What do you want to see?

 

Data Descriptions

Data Unit Description
Set Item Type Native
Equipment Properties Hevy side flash pressure Pressure psia The heavy liquor flashing pressure
Weak side flash pressure Pressure psia The heavy liquor flashing pressure
Top of Page

Equipment Properties

Top of Page

Example of using equipment

Top of Page

Method&Equations

Each side the liquor is flashed at the given pressure, the saturated liquor leaves the body at the given pressure, the vapor leaves at the lower selected pressure.

Top of Page

Warnings

Being a composite item – each component may call its warnings.

Top of Page

Errors

Being a composite item – each component may call its errors.

Top of Page

© 2007 American Process Inc. All rights reserved.