Equipments - Selective Split

Use the Selective Split to split the inlet stream into two outlet streams.
Specify the fraction of the inlet components to the first outlet flow stream. The inlet components of which the fraction is unspecified goes to the first outlet stream.

What do you want to see?

 

Data Description

Data Unit Description
Set Item Type Native
Equipment Properties Component Inlet component to the outlet streams.
Amount to First Outlet Fraction or Percent Fraction The fraction of inlet component  to be sent to the first outlet stream.
Top of Page

Equipment Properties

Top of Page

Example of using equipment

Top of Page

Method&Equations

The inlet flow is the sum of the first and second outlet flows:

        Inlet Flow=First Outlet Flow+Second Outlet Flow

A componet flow in the first outlet is calculated as follows:

       Componet flow in the first outlet=Component flow in the inlet *Amount to First_Outlet

A componet flow in the second outlet is calculated as follows:

       Componet flow in the first outlet=Component flow in the inlet *(1-Amount to First_Outlet)

The components of which the amount is not specified goes to the first outlet stream.

Top of Page

Warnings

Top of Page

Errors

Missing Stream(s)!

Top of Page

© 2007 American Process Inc. All rights reserved.