Equipments - Volume Flow Split

Use the Volume_Flow_Split to split an inlet stream into two to five outlet streams by volume flow.
Set the flow for each outlet stream excepting the last one. The model assigns the remaining flow to the last outlet.
The model satisfies as many streams as possible, beginning with the first outlet stream.
Outlet stream state and composition are the same as the inlet.

What do you want to see?

 

Data Description

Data Unit Description
Set Item Type Native
Equipment Properties First Outlet Flow Volume Flow Volume flow in first outlet stream.
Second Outlet Flow Volume Flow lbs/hr Volume flow in second outlet stream.
Third Outlet Flow Volume Flow lbs/hr Volume flow in third outlet stream.
Fourth Outlet Flow Volume Flow lbs/hr Volume flow in fourth outlet stream.
Fifth Outlet Flow Volume Flow lbs/hr Volume flow in fifth outlet stream.
Top of Page

Equipment Properties

Top of Page

Example of using equipment

Top of Page

Method&Equations

If there is not enough inlet flow to satisfy all the flows you specify, the model satisfies as many as possible, beginning with the first outlet stream. The model will not change the flow in an Outlet Flow Given stream.

The model assigns the remaining flow to the last outlet. The model satisfies all specified flows equally.

In all cases the outlet's state and composition are set to the inlet state and composition.

The inlet flow is the sum of the outlet flows:

        Inlet Flow=Sum of the Outlet Flows

Top of Page

Warnings

Top of Page

Errors

Missing Stream(s)!

Top of Page

© 2007 American Process Inc. All rights reserved.