Equipments -Consistency Split

Use the Consistency_Split to split a pulp stream according to specific outlet consistency. The model thickens the stream by splitting off some of the liquor. The inlet stream contains both, liquor and solids.

What do you want to see?

 

Data Description

Data Unit Description
Set Item Type Native
Equipment Properties First Outlet Consistency Fraction or Percent Fraction The desired consistency of the First_Outlet stream.
Inlet Solids to First Outlet Fraction or Percent Fraction The fraction of the inlet solids that remain in the First_Outlet stream.
Second Outlet Consistency Fraction or Percent Fraction The consistency of the Second_Outlet stream.
Split Water Only If checked (True) all dissolved species go to the first outlet stream and water and suspended solids go to the second outlet stream.
Top of Page

Equipment Properties

Top of Page

Example of using equipment

Top of Page

Method&Equations

The flow of solids is based on the solids fraction in the First_Outlet stream.

The user can enter the fraction of inlet solids in the First_Outlet or this may be calculated, given the consistency in the First and Second_Outlet as the equation shows:

        SOLFRC = (CONSO1 * (CONSO2 * LIQFLOI + (CONSO2 - 1.0) * SOLFLOI)) / ((CONSO2 - CONSO1) * SOLFLOI)

where:

        SOLFRC is the solids fraction for the First_Outlet

        SODFLOI is the flow of solids in the inlet

        LIQFLOI is the flow of liquor in the inlet

        CONSO1 is the First_Outlet consistency

        CONSO2 is the Second_Outlet consistency

To calculate the required flow of liquor in the first outlet stream necessary to meet the specified consistency, the model uses the following:

        LIQFLO = SLDFLO * (1.0 - CONS) / CONS

where:

       LIQFLO is the required flow of liquor

       SLDFLO is the inlet solids flow

       CONS is the First_Outlet consistency

The calculated flow of liquor is sent with the first outlet stream. The remainder is sent with the second outlet stream.

Top of Page

Warnings

Zero flow entering !

Inlet consistency greater than requested!

Consistency not feasible!

No liquor entering!

Solid flow is zero!

Consistency is not feasible!

Top of Page

Errors

Missing Stream(s)!

Top of Page


Related Topics
OCC Plant Sample

© 2007 American Process Inc. All rights reserved.